Clinical Chemistry

::Liquid-stable up to the expiry date, even after opening
::Ready-to-use - no reconstitution errors, directly available for stat analysis
::Typical stability12 –24 months
::Monoreagent or4 +1 format mainly
::Multi-purpose kits in different sizes for small and large laboratories
::Special kits for automated systems
::Applications available for a variety of automated systems

Product

ACID PHOSPHATASE

Specimen Fresh serum
Product code  D1A10...*
· Reconstituted stability  2 – 8 °C
· Linearity up to 75 U/L
· Wavelength 405 nm

ALAT (GPT) (IFCC mod.)

• Liquid-stable, ready-to-use reagent (4+1)
• IFCC recommended procedure
Product code D1G80...*
• Mixed reagent stability 4 weeks at 2 – 8 °C
• Linearity up to 600 U/L
• Wavelength 340, 334 or365 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

Albumin

• Liquid-stable, ready-to-use mono reagent
• Bromocresol green method
Product code D1A20...*
• Linearity up to 6 g/dL
• Wavelength 546 nm, 540 – 600 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

Alkaline phosphatase DGKC

• Liquid-stable, ready-to-use reagent (4+1)
• DGKC recommended procedure
Product code D1A30...*
• Mixed reagent stability 4 weeks at 2 – 8 °C
• Linearity up to 4500 U/L
• Wavelength 405 nm, 400 – 420 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

a-Amylase

• Liquid-stable, ready-to-use reagent (4+1)
• EPS-G7 method
Product code D1A50... *
• Similar to IFCC recommended procedure
• Serum, plasma or urine
• Linearity up to 4000 U/L
• Mixed reagent stability 6 months at 2 –8 °C
• Wavelength 405 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

ASAT (GOT) (IFCC mod.)


• Liquid-stable, ready-to-use reagent (4+1)
• IFCC recommended procedure
Product code D1G60...*
• Mixed reagent stability 4 weeks at 2 – 8 °C
• Linearity up to 1000 U/L
• Wavelength 340, 334 or 365 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

ATP Hexokinase


• Liquid-stable, ready-to-use reagent
• Indirect indicator for survival rate of erythrocytes
Product code
• Determination of ATP in erythrocyte concentrates and
other sample material
Standart : DDS ATP std

Bicarbonate


• Liquid-stable, ready-to-use reagent
• Enzymatic test using synthetic NADH analogue
Product code D1B70... *
• Calibration stability10 days
• Linearity up to 50 mmol/L
• Wavelength 405 or 415 nm
Std: DDS Bicarbonate Std
Cotrol : DDS Bicarbonate control (one level)

Bile acids


• Colorimetric endpoint test
• Reconstitution required
Product code
• Linearity up to 150 ΅mol/L
• Wavelength 540 nm
Calibrator: DDS Calibrator
Standart : DDS Bile acids std (included in kit)
Bilirubin Direct DA
• Liquid-stable, ready-to-use reagent
• DCA method
Product code D1B20 ..*
• Linearity up to10 mg/dL
• Wavelength 546 nm, 540 – 560 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

Bilirubin Direct SA


• Liquid-stable, ready-to-use reagent
• DMSO method
Product code D1B25 ..*
• Linearity up to10 mg/dL
• Wavelength 546 nm, 540 – 560 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

Bilirubin Total DA


• Liquid-stable, ready-to-use reagent
• DCA method
Product code D1B40... *
• Linearity up to 30 mg/dL
• No interferences by lipemia, hemoglobin and ascorbic acid
• Wavelength 546 nm, 540 – 560 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

Bilirubin Total SA


• Liquid-stable, ready-to-use reagent
• DMSO method
Product code D1B45... *
• Linearity up to 30 mg/dL
• No interferences by lipemia, hemoglobin and ascorbic acid
• Wavelength 546 nm, 540 – 560 nm
Calibrator: DDS Calibrator
Contols : DDS Control N, DDS Control A

Calcium AS


• Liquid-stable, ready-to-use mono reagent
• Arsenazo III method
Product code D1C05... *
• Lipid clearing system
• Serum, plasma or urine
• Linearity up to 25 mg/dL
• Wavelength 650, 630 – 670 nm, Hg623 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

Calcium CPC


• Liquid-stable, ready-to-use reagent (1+1)
• o-Cresolphthalein complexone method
Product code D1C10...*
• Lipid clearing system
• Minimal CO2 influence
• Serum, plasma or urine
• Linearity up to 20 mg/dL
• Wavelength 570, 550 – 590 nm, Hg 578 nm

Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

Chloride


• Liquid-stable, ready-to-use mono reagent
• Thiocyanate method
Product code D1C30...*
• Linearity up to 130 mmol/L
• Wavelength 500 nm, Hg546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

Cholesterol


• Liquid-stable, ready-to-use mono reagent
5 minute endpoint version, 10 minute endpoint version,
• CHOD-PAP method - Trinder reaction
Product code D1C38...*, D1C37...*
• Linearity up to 750 mg/dL
• Wavelength 500 nm, Hg546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A,DDS Lipid control

Cholinesterase


• Liquid-stable, ready-to-use reagent (4+1)
• Butyrylthiocholine method
Product code D1C45...*
• Linearity up to 20.000 U/L
• Serum or plasma
• Wavelength 405 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

CK-MB


• Liquid-stable, ready-to-use reagent (4+1)
• Immunoinhibition method
Product code D1C60...*
• Based on DGKC/IFCC recommendation
• Linearity up to 2000 U/L CK (may vary according to specific applications)
• Wavelength 340 nm, Hg334 nm
Calibrator: DDS Calibrator
Control : DDS CK-MB control

CK-NAC


• Liquid-stable, ready-to-use reagent (4+1)
• DGKC/IFCC recommended procedure
Product code D1C50...*
• Linearity up to 2000 U/L(may vary according to specific applications)
• Wavelength 340 nm, Hg365 nm, Hg334 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS CK-MB control

Creatinine


• Liquid-stable, ready-to-use reagent (4+1)
• Jaffι method
Product code D1C80...*
• Serum, plasma or urine
• Linearity up to15 mg/dL
• Wavelength Hg492 nm (490 – 510 nm)
Supplementary reagents: Creatinine Urine diluent
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

Creatinine PAP


• Liquid-stable, ready-to-use reagent (1+3)
• Enzymatic PAP method
Product code D1C90...*
• Serum, heparin plasma or urine
• Linearity up to 30 mg/dL
• Wavelength Hg546 nm
Controls:TruLab N, TruLab P and TruLab Urine (two levels)

Ethanol


• Liquid-stable, ready-to-use reagent
• Enzymatic UV test
Product code D1E20...*
• Serum or plasma
• Wavelength 380 nm
Standarts : Ethanol std (different concentrations)
Control : DDS Ethanol control

Free cholestero

l
• Liquid-stable, ready-to-use mono reagent
• CHOD-PAP method - Trinder reaction
Product code D1F20..*
• Linearity up to 400 mg/dL
• Wavelength 546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS Lipid control

Free glycero

l
• Liquid-stable, ready-to-use mono reagent
• GPO method - Trinder reaction
Product code D1F30...*
• Linearity up to 250 mg/dL
• Wavelength 500 nm, Hg546 nm
Std:Triglycerides Std (with additional value for glycerol)
Controls : DDS Control N, DDS Control A

Gamma-GT (Szasz mod./IFCC stand.)


• Liquid-stable, ready-to-use reagent (4+1)
• Method : Szasz
Product code D1G05...*
• Mixed reagent stability 4 weeks at 2 – 8 °C
• Linearity up to1200 U/L
• Wavelength 405 nm (400 – 420 nm)
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

GLDH DGKC


• Liquid-stable, ready-to-use reagent
• Method according to DGKC recommendation1972
Product code D1G50...*
• Linearity up to120 U/L
• Wavelength 340 nm, Hg334 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

Glucose GOD


• Liquid-stable, ready-to-use mono reagent
5 minute endpoint version
• GOD-PAP method - Trinder reaction
Product code D1G25...*
• Linearity up to 400 mg/dL
• Wavelength 500 nm, Hg546 nm
10 minute endpoint version
Product code D1G25...*
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

Glucose Hexokinase


• Liquid-stable, ready-to-use reagent (4+1)
• Hexokinase method
Product code D1G40...*
• Mixed reagent stability 3 months at 2 – 8 °C
• Serum, plasma or urine
• Linearity up to 900 mg/dL
• Wavelength 340 nm, Hg334 nm, Hg365 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

?-HBDH


• Liquid-stable, ready-to-use reagent (4+1)
• DGKC recommended method
Product code D1H10...*
• Linearity up to2400 U/L
• Wavelength 340 nm, Hg334 nm, Hg365 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

HDL-C direct 3rd new


• Liquid-stable, ready-to-use reagent
• Direct method
Product code D1H40...*
• Endpoint assay
• Linearity up to180 mg/dL
• Wavelength 600 nm/700 nm (bichromatic)
Calibrator: DDS HDL / LDL Calibrator
Controls : DDS Lipid Control

HDL-C Direct


• Liquid-stable, ready-to-use reagent
• Direct immunoinhibition method
Product code D1H35...*
• Endpoint assay
• Linearity up to180 mg/dL
• Wavelength 600 nm/700 nm (bichromatic)
Calibrator: DDS HDL / LDL Calibrator
Controls : DDS Lipid Control

Hemoglobin


• Ready-to-use, mono reagent
• Concentrated reagent
• Hemiglobincyanide method
Product code D1H65...*
• Linearity up to 40 g/dL
• Wavelength 540 nm, Hg546 nm

Homocysteine


• Liquid-stable, ready-to-use reagent
• Enzymatic cycling method
Product code D1H80...*
• Linearity up to 50 ΅mol/L
• No cystathionine interference
• Wavelength 340 nm
Calibrator: DDS Homocysteine Calibrator
Controls : DDS Homocysteine Controls (two levels)

ί-Hydroxybutyrate


• Liquid-stable, ready-to-use reagent
• Enzymatic endpoint method
Product code D1H70...*
• Serum or plasma
• Linearity up to 6.9 mmol/L
• Wavelength 546 nm
Std: DDS ί-Hydroxybutyrate std
Controls : DDS Control N, DDS Control A

Iron Ferene


• Liquid-stable, ready-to-use reagent
• Ferene method
Product code D1I10...*
• Linearity up to 1000 ΅g/dL
• Wavelength 600 nm, Hg595 nm
Calibrator: DDS Calibrator
Std : Iron std
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

Iron Ferrozine


• Liquid-stable, ready-to-use reagent
• Ferrozine method
Product code D1I15...*
• Linearity up to 1000 ΅g/dL
• Wavelength 600 nm, Hg595 nm
Calibrator: DDS Calibrator
Std : Iron std
Controls : DDS Control N, DDS Control A

Lactate


• Liquid-stable, ready-to-use reagent
• LDH UV endpoint method
Product code D1L10...*
• Determination in plasma
• Wavelength 340 nm/Hg334 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

LDH DGKC


• Liquid-stable, ready-to-use reagent (4+1)
• DGKC recommended method
Product code D1L20...*
• Linearity up to 2400 U/L
• Wavelength 340 nm, Hg365 nm, Hg334 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

LDL-C direct 3rd new


• Liquid-stable, ready-to-use reagent
• Direct method
Product code D1L35...*
• Endpoint assay
• Linearity up to 400 mg/dL
• Wavelength 600 nm/700 nm (bichromatic)
Calibrator: DDS HDL / LDL Calibrator
Controls : DDS Lipid Control

LDL-C Direct


• Liquid-stable, ready-to-use reagent (4+1)
• Selective direct single measurement
Product code D1L40...*
• Endpoint assay
• Linearity up to 400 mg/dL
• Wavelength 600 nm/700 nm (bichromatic)
Calibrator: DDS HDL / LDL Calibrator
Controls : DDS Lipid Control

Lipase DC


• Liquid-stable, ready-to-use reagent (4+1)
• Direct colorimetric method
Product code D1L50...*
• Substrate in microemulsion - high specificity
• Linearity up to 300 U/L
• Wavelength 580 nm, Hg578 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

Magnesium


• Liquid-stable, ready-to-use mono reagent
• Xylidyl blue method
Product code D1M10...*
• Lipid clearing system
• Serum, plasma, urine or CSF
• Calibration stable for 4 weeks
• Linearity up to 5 mg/dL
• Wavelength: 520, 500 – 550 nm, Hg546 nm,
628, 570– 650 nm, Hg623 nm
Calibrator: DDS Calibrator
Std : Mg std
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

NEFA new


• Liquid-stable, ready-to-use reagent
(Non-esterified fatty acids)
• Innovative Trinder method
Product code D1N20...*
• Serum or plasma
• No risk due to hazardous substances
Std : DDS NEFA Std
Controls : DDS Lipid Control

Pancreatic amylase


• Liquid-stable, ready-to-use reagent (4+1)
• EPS-G7 method
Product code D1A60... *
• Immunoinhibition of salivary amylase
• Based on IFCC recommendation
• Serum, plasma or urine
• Linearity up to 4000 U/L (may vary according to specific applications)
• Wavelength 405 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

Phosphorus UV


• Liquid-stable, ready-to-use,mono reagent
• Molybdate method
Product code D1P10...*
• Lipid clearing system
• Serum, plasma or urine
• Linearity up to 30 mg/dL
• Wavelength 340 nm, Hg334 nm, Hg365 nm
Calibrator: DDS Calibrator
Std : Phosphorus std
Controls : DDS Control N, DDS Control A, DDS urine controls (two levels)

Phospholipids new


• Liquid-stable, ready-to-use reagent
• Enzymatic colorimetric test
Product code D1P20...*
• Linearity up to13.3 mmol/L
• Wavelength 570 nm
Standars : DDS P. Lipid std
Controls : DDS Lipid Control

Total protein


• Liquid-stable, ready-to-use,mono reagent
• Biuret method
Product code D1T15...*
• Mixed reagent stability1 year at 2 – 8 °C
• Linearity up to15 g/dL
• Wavelength 540 nm, Hg546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

Microprotein


• Liquid-stable, ready-to-use mono reagent
• Measurement in urine or CSF
Product code D2M30...*
• Pyrogallol red method
• Linearity up to 3000 mg/L
• Wavelength 600 nm (580 – 600 nm), Hg578 nm
Std: Microprotein Std
Control : DDS urine controls (two levels)

Triglycerides


• Liquid-stable, ready-to-use single reagent
5 minute endpoint version, 10 minute endpoint version
• GPO method - Trinder reaction
Product code D1T26...*, D1T25...*
• Linearity up to 1000 mg/dL
• Wavelength 500 nm, Hg546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A,DDS Lipid control

UIBC ( Manuel and automated system)


• Liquid-stable, ready-to-use reagent
(Unsaturated iron binding capacity)
• Ferrozine method
Product code D1I20...*
• Serum or heparin plasma
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A

Urea


• Liquid-stable, ready-to-use reagent (4+1)
• Urease - GLDH method
Product code D1U20...*
• Serum, plasma or urine
• Linearity up to 300 mg/dL
• Wavelength 340 nm, Hg334 nm, Hg365 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A,DDS Urine control (two levels)

Urea CT


• Liquid-stable, ready-to-use reagent
• Colorimetric endpoint method (Berthelot)
Product code D1U30...*
• Serum, plasma or urine
• Linearity up to 400 mg/dL
• Wavelength 578 nm, 560 – 600 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A,DDS Urine control (two levels)

Uric acid TBHBA


• Liquid-stable, ready-to-use reagent (4+1)
• Uricase-TBHBA method
Product code D1U80...*
• Serum, plasma or urine
• Linearity up to 20 mg/dL
• Wavelength 520, 500 – 550 nm, Hg546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A,DDS Urine control (two levels)

Uric acid TOOS


• Liquid-stable, ready-to-use reagent (4+1)
• Uricase-TOOS method
Product code D1U75...*
• Serum, plasma or urine
• Linearity up to 20 mg/dL
• No ascorbate interference
• Wavelength 550 nm, Hg546 nm
Calibrator: DDS Calibrator
Controls : DDS Control N, DDS Control A,DDS Urine control (two levels)

 
Firmamύz Bize ulaώύn Ana sayfa